02 932 1711
086 360 8600
LINE ID1: prctec-center
LINE ID2: prcsense

Product Category


49
>> Computer Controlled Measurement Amplifiers
1

The DASIM Universal Amplifier offers computer-controlled signal conditioning of manifold sensors. It has 1 DSP per channel. Signal output is with high precision via analog outputs and digitally via Ethernet and CAN. Parameter setting is done with the software DaSoft. Signal filtering can be configured from 3..3000 resp. 6..6000 Hz at 20 resp. 40 kS/s sample rate.
2

The DASIM CF Amplifier offers computer-controlled signal conditioning of strain gauge bridges and inductive sensors. It has 1 DSP per channel. Signal output is with high precision via analog outputs and digitally via Ethernet and CAN. Parameter setting is done with the software DaSoft. Signal filtering can be configured from 10..1000 Hz.
3

The SIQUAD Universal Amplifier offers computer-controlled signal conditioning of manifold sensors. It has 1 DSP per channel. Signal output is digital via Ethernet and CAN and optional with high precision via analog outputs. Parameter setting is done with the software DaSoft. Signal filtering can be configured from 3..3000 Hz at 20 kS/s sample rate.
4

The SIQUAD DMS4 (Strain Gauge) Amplifier offers computer-controlled signal conditioning of strain gauge bridges. It has 1 DSP per unit. Signal output is digital via Ethernet and CAN and optional with high precision via analog outputs. Parameter setting is done with the software DaSoft. Signal filtering can be configured from 3..3000 Hz at 20 kS/s sample rate.
5

The SIQUAD DC Amplifier offers computer-controlled signal conditioning of voltage or current signals. It has 1 DSP per unit. For high voltage up to 1000 V, a 2-channel version is available. Signal output is digital via Ethernet and CAN and optional with high precision via analog outputs. Parameter setting is done with the software DaSoft. Signal filtering can be configured from 3..3000 Hz at 20 kS/s sample rate.
6

The SIQUAD DC2HV Amplifier offers computer-controlled signal conditioning of high voltage or current signals. It has 1 DSP per unit. Signal output is digital via Ethernet and CAN and optional with high precision via analog outputs. Parameter setting is done with the software DaSoft. Signal filtering can be configured from 3..3000 Hz at 20 kS/s sample rate. The SIQUAD Power Measurement Amplifier is used to measure electrical power. The input data, Voltage and Current, are measured with 20 kHz per channel. With these results the amplifier computes RMS of voltage and current, frequency, power factor and active and apparent power. For this the amplifier contains a digital signal processor (DSP). The output of the calculated values is available after the first measured period and will be send digitally through Ethernet and CAN.
7

The SIQUAD Potentiometer Amplifier offers computer-controlled signal conditioning of potentiometers. It has 1 DSP per unit. Signal output is digital via Ethernet and CAN and optional with high precision via analog outputs. Parameter setting is done with the software DaSoft. Signal filtering can be configured from 3..3000 Hz at 20 kS/s sample rate.
8

The SIQUAD Thermocouple Amplifier offers computercontrolled signal conditioning of thermocouples. It has 1 DSP per unit. Signal output is digital via Ethernet and CAN and optional with high precision via analog outputs. Parameter setting is done with the software DaSoft. Signal filtering can be configured from 3..3000 Hz at 10 kS/s sample rate.
9

The SIQUAD Pt100 Amplifier offers computer-controlled signal conditioning of RTD sensors. It has 1 DSP per unit. Signal output is digital via Ethernet and CAN and optional with high precision via analog outputs. Parameter setting is done with the software DaSoft. Signal filtering can be configured from 3..3000 Hz at 10 kS/s sample rate.
10

The SIQUAD ICP4 Amplifier offers computer-controlled signal conditioning of piezo-electric sensors. It has 1 DSP per unit. Signal output is digital via Ethernet and CAN and optional with high precision via analog outputs. Parameter setting is done with the software DaSoft. Signal filtering can be configured from 3..3000 Hz at 20 kS/s sample rate.
11

The SIQUAD Frequency Amplifier offers computer-controlled signal conditioning of arbitrary periodic frequency signals. Each of the 2 channels has 2 differential tracks with AC coupling and a following 4-step amplifier stage. So signals with amplitudes from 500 mVpp to 100 Vpp can be handled. Each channel has an additional digital input. An isolated sensor supply is integrated. There is 1 DSP per unit. Signal output is digital via Ethernet and CAN and optional with high precision via analog outputs. Parameter setting is done with the software DaSoft.
12

Characteristics The SIQUAD DIO-8 Plug-in Unit offers computer-controlled signal conditioning of up to 8 digital input signals and drives 8 relay outputs. The inputs are insulated by optocouplers. The relay outputs can be configured per channel by jumpers to make or break. Front panel LEDs indicates switching states of inputs and outputs.

The SIQUAD AO4 Plug-in Unit provides up to 4 analog outputs. The signal level can be set by the parameter setting software or via a LabVIEW application.
13

The CAN Interface Unit offers synchronous acquisition of CAN messages from a CAN bus. These data are put on the internal high-speed bus and are processed simultaneously with the other measurement data by the central unit. They can be handled further with an appropriate data acquisition software like DAQSoft or DASYLab (by using the DASYLab driver). Parameter setting is done with the software DaSoft. The CAN-Interface can be used with both DASIM and SIQUAD systems.
14

The Central Unit is the interface between the internal high-speed bus, the Ethernet connection, an RS 232 interface, and the internal RS 485 bus. It is a plug-in unit for the housing and provides the clock for the amplifiers as well as external clocking and synchronization for additional housings resp. chassis. External trigger signals are also administered by the central unit. A remote control can be connected via the remote interface. Parameter setting of the amplifiers is done with the software DaSoft via the Ethernet or RS 232 interface of the central unit
15

The Measurement Software DAQSoft offers acquisition and visualization of data for DASIM and SIQUAD systems. First parameters of the amplifiers are set with DaSoft. DaSoft provides the system settings and generates an interface file “DDL.int“ with the necessary specifications for data acquisition. DAQSoft takes this information of the “DDL.int“ automatically. The file is always updated with actual data after each communication of DaSoft with the measurement system. If changes were done in the system with DaSoft, it will be automatically recognized by DAQSoft and notified. Therefore it is not possible to measure with wrong parameters.
16

The DASIM and SIQUAD Amplifiers fit into (standard) 19” chassis and desktop housings. The housings can be tailored to customerspecific needs concerning number of units and power supply. For mobile applications a wide-range power supply is available.
17

The SIQUAD CAN Compact Module Uni4 offers computer-controlled signal conditioning of various sensors in 1 module. It has 1 DSP per channel. Signal output is digital via CAN. The protocol is CAN 2.0B. Parameter setting is done with the software DaSoft via a USB-to-CAN interface. Signal filtering can be configured from 3..3000 Hz at 20 kS/s sample rate.
18

The SIQUAD CAN Compact Modules offer computer-controlled signal conditioning of various sensors. There are a universal of sensor-speciflc amplifiers available.
19

The SIQUAD CAN mounting-rail module Uni offers computer-controlled universal signal conditioning of various sensors. There is a 1- or 2-channel version available. It has 1 DSP per channel. Signal output is digital via CAN. Protocol is CAN 2.0B. Parameter setting is done with the software DaSoft via a USB-to-CAN interface. Signal filtering can be configured from 3..3000 Hz at 20 kS/s sample rate.
20

The SIQUAD CAN Stick offers computer-controlled signal conditioning of various sensors. It has 1 DSP per unit. There are 2 versions depending on the sensor requirements. Signal output is digital via CAN. Protocol is CAN 2.0B. Parameter setting is done with the software DaSoft via a USB-to-CAN interface. Signal filtering can be configured from 3..2000 Hz at 20 kS/s sample rate.
21

The SIQUAD Ethernet Compact Module Uni offers computer-controlled signal conditioning of various sensors. The universal amplifier is using one separate DSP per channel. Signal output is digital via TCP/IP. Parameter setting is done with the software DaSoft. Signal filtering can be configured from 3..3000 Hz at 20 kS/s sample rate
22

The SIQUAD Ethernet Compact Modules offer computer-controlled signal conditioning of various sensors. There are sensor-specific amplifiers available with 1 DSP per amplifier unit. Signal output is digital via TCP/IP. Parameter setting is done with the software DaSoft. Signal filtering can be configured from 3..3000 Hz at 20 kS/s sample rate.
23

The AD converter AD-ETH-250 offers synchronous acquistion of fast DC signals. Measurement data are put out via an Ethernet interface by TCP/IP(UDP on request)