
Product Category
- 1GHM product
- 2UV Sensor / Amplifier
- 3เครื่องวัดอัตราการไหล
Flowmeter - 4Encoder
- 5Electrical Engineering
- Installation safety testers [1]
- Oscilloscopes [2]
- Multimeters [3]
- Current clamp multimeters [4]
- Voltage testers [5]
- Waveform generators [6]
- Spectrum analyzers [7]
- Cable locators & testers [8]
- Power analyzers [9]
- LCR & component tester [10]
- Analog meters & built-in devices [11]
- Signal level meters [12]
- Electronics data loggers [13]
- Workshop equipment for electronics [14]
- 6UV Meter / Controller
- 7UV Lamp / LED / Laser
- 8เครื่องวิเคราะห์ก๊าซ
Combustible Gas Analyzer - 9เครื่องวัดก๊าซ
Gas Detector-Portable - 10USB Microscope
- 11เครื่องวัดฝุ่น - Air Quality
- 12เครื่องวิเคราะห์การเผาไหม้ก๊าซในรถยนต์
Automotive Micro Bench for CO, CO2 and HC - 13เครื่องวัดและบันทึกข้อมูลขนาดจิ๋ว
Mini Data Logger - 14Sensor วัดระยะ
Ultrasonic Distance Sensor - 15เครื่องมือวัดอุตุนิยมวิทยา
- 16Ultrasonic anemometer
- 17Panel Meter
- 18CMOS Sensor Wide dynamic range
- 19control valves
- 20Sensors(prctec)
- 21รางป้องกันสายเคเบิ้ล
Cable Protectors - 22Power supply
- 23ตัวแปลงสัญญาณไฟฟ้ามาตรฐาน (ZIEHL)
Measuring Transducers- DC Current Voltage [1]
- AC/DC Current-Voltage [2]
- AC - Current - Transducers [3]
- EC - Decharation of Comformity STWQ [4]
- Current Relay For Photovoltaic – systems [5]
- Twilight Switches [6]
- Phase-Monitor Relays Type PS [7]
- Voltage-monitor Relays [8]
- Current-Relays for current-recognition Type STWs [9]
- Electronic Current-Transformers Current-Sensors [10]
- Frequency- and Speed-Relays [11]
- 24เซ็นเซอร์วัดความชื้นน้ำมัน/Dew point
- 25เซนเซอร์วัดความชื้นในน้ำมัน
Oil humidity sensor - 26เครื่องทดสอบแรงดันไฟฟ้า
Voltage Tester - 27ดิจิตัลมัลติมิเตอร์
Digital Multimeter - 28ดิจิตอลแคลมป์มิเตอร์
Digital Clamp Meter - 29Appliance Tester
- 30เครื่องทดสอบความปลอดภัย
Safety Instrument - 31Installation Tester
- 32เครื่องวัดแสงแดดและอุณหภูมิ
light and Temperature Instrument - 33เครื่องมือทดสอบไฟฟ้า
Electrical Tester - 34AC Current Measurements
- 35Surge Protector
- 36Surge Protector_K-surge
- 37LINE/NOISE FILTER
- 38MOV Test - เครื่องวัด/ทดสอบอุปกรณ์ฟ้าผ่า
- 39Hour meter /Timer / Counter
- 40เครื่องวัดไฟฟ้า
- 41เซ็นเซอร์วัดระยะ
Laser distance, Ultrasonic sensor... - 42Solenoid valves
- 43Control Relay
- 44DIS Sensor
- 45Current sensor / Current relay / Voltage sensor
- 46Signal Conditioning / Isolation
- 47เครื่องวัดไฟฟ้าสถิต
Electrostatic field meter - 48Vibration / Shock Measurement
- 49Computer Controlled Measurement Amplifiers
- 50Torque Measurement
- 51Viscometer
เครื่องวัดความหนืด - 52Wireless Sensors
- 53Brix - เครื่องวัดความหวาน
- 54PID Controller
- 55Signal Simulator
- 56HMI Touch Screen & Controller
- 57เครื่องควบคุมการฟักไข่
- 58PROFESSIONAL DATA LOGGER
- 59Water leak detector - เครื่องตรวจจับน้ำรั่วซึม
- 60Microscope - กล้องจุลทรรศน์, กล้องขยาย
- 61เครื่องชั่งอุตสาหกรรม/LAB
- 62Calibration weights - น้ำหนัก-สอบเทียบ
- 63บริการให้เช่าเครื่องมือวัด
- 64ELECTROMAGNETIC FIELD TESTER - เครื่องวัดสนามแม่เหล็กและสนามไฟฟ้า
- 65REFRACTOMETER
- 66Leak detector - เครื่องตรวจสอบรอยรั่วซึม
- 67Spectrum Analyzers
- 68Heat detector อุปกรณ์ตรวจจับความร้อน
- 69EV Charger
- 70Meter ห้องเย็น/ตู้แช่แข็ง
- 71Heater อุตสาหกรรม
- 72Premosys
- 73QR Code Reader / Barcode Reader สำหรับอุตสาหกรรมและไลน์ผลิต
- 74สมัครงาน
- 75Download Brochure/Catalog
46
>>
Signal Conditioning / Isolation
>>
Signal Conditioning
[2]
The TSA-FIL Module offers isolated signal conversion and filtering of voltage and current signals. Voltage and current inputs can be combined with voltage and current outputs. The desired configuration should bespecifiedwithorder.
The TSA-DMS Module offers signal conditioning of strain gauge bridges with 4-wire or 6-wire technology. Standard ranges are 2, 4, 10 mV/V. Manual offset correction can be done with a Zero trimmer. Sensor supply (standard 5 V DC) is isolated, provided by the module. Depending on the base configuration the module has voltage and current outputs.
The TSA-Poti Module offers signal conditioning of potentiometers in 3-wire or 5-wire technology with resistances from 350..1000 Ω. Standard ranges are 100, 50, 25 and 12,5 %. Manual offset correction can be done with a Zero trimmer. Sensor supply (standard 5 V DC) is isolated, provided by the module. Depending on the base configuration the module has voltage and current outputs.
The TSA-DC Module offers signal conditioning of Shunt sensors or other arbitrary DC and AC sources. Switchable standard ranges are 150 mV, 500 mV, 1 V and 10 V. The input is differential. Depending on the base configuration the module has voltage and current out- puts.
1 or 2 analog outputs, plug-in filters 10 Hz..10 kHz (standard), 4-pole Butterworth or Bessel characteristics, supply voltage 24 V DC, DIN rail mounting TS35
The TSA-TC Module offers signal conditioning of thermocouples (standard types J, K and T). Linearisation is done by the module. Maximum measurement range (type K) is -100°C to 1200°C. The standard module has a fixed range (-100°C to +100°C, or +200°C, +500°C, +1000°C, +1200°C) plus type to be specified with order. Calibration is done for this range. Optionally up to three switchable ranges are selectable. The CJC is integrated in the connector, cable break is indicated by an LED. Depending on the base configuration the module has voltage and current outputs.
The TSA-XX-RMS Modules offer signal conditioning of FIL, DMS (strain gauge), Poti, DC, and ICP ® applications with parallel (True) RMS processing of the output signal. Matching sensor supply is provided by the module. It has two voltage outputs (signal ± 10 V and RMS 0..7.07 V).
The TSA-XX-RMS Modules offer signal conditioning of FIL, DMS (strain gauge), Poti, DC, and ICP ® applications with parallel (True) RMS processing of the output signal. Matching sensor supply is provided by the module. It has two voltage outputs (signal ± 10 V and RMS 0..7.07 V).
The TSA-IF Module offers isolated pulse forming of signals from in- ductive speed indicators, Hall devices, incremental transducers and other pulse generators. Sensor supply (5 V DC) is isolated, provided by the module. It has a TTL output and optionally an Open Collector output. There is a 2-channel and 3-channel version available.
The TSA-Arithmetic Modules offer isolated combination of voltage signals. One of the four basic arithmetic operations as well as power (multiplication with adjacent averaging) are available. Depending on the base configuration the module has voltage and current outputs.